BIO RAD PowerPac 200 Instruction Manual

Browse online or download Instruction Manual for Power supply units BIO RAD PowerPac 200. BIO RAD PowerPac 200 Instruction manual User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 37
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
INSTRUCTION MANUAL
AND
Catalog Numbers
PowerPac 1000
165-5054
165-5055
PowerPac 3000
165-5056
165-5057
165-5058
165-5059
165-5060
POWER PAC 3000
POWER PAC 1000
0
EXIT
CLR
8
5
2
7
4
1
9
6
3
–+
–+
–+
–+
POWER PAC 3000
Page view 0
1 2 3 4 5 6 ... 36 37

Summary of Contents

Page 1 - POWER PAC 1000

INSTRUCTION MANUALANDCatalog NumbersPowerPac 1000165-5054165-5055PowerPac 3000165-5056165-5057165-5058165-5059165-5060POWER PAC 3000POWER PAC 10

Page 2 - TABLE OF CONTENTS

Table 2. (continued)Manual Mode Operation Step Procedure Description4. Select Manual. Press the appropriate soft key.5. Select the constant Use the s

Page 3

Table 2. (continued)Manual Mode OperationStep Procedure Description9. Select one of the following:a. TIME a. TIME: To specify automatic time control.

Page 4

Figure 3. Manual Mode Flow ChartMANUAL >>PROGRAM >>>>>>>>CONSTANTxxx WTIME/V-HOUR >>xxxx VSET: xxxx V / xxx mA /

Page 5 - 1.0 INTRODUCTION

4.0 PROGRAM MODE OPERATIONThere are four selections under Program mode:• Create a method• Edit a method• Run a method• View a methodEach of these sel

Page 6

4.1 CREATE AND RUN A METHODTable 4.Procedure for Creating and Running a MethodStep Procedure Description1. Select PROGRAM from themain menu.2. Select

Page 7 - 2.0 CONTROL FEATURES

Table 4. (continued)Procedure for Creating and Running a MethodStep Procedure Description8. Program the next step or save the program.9. Enter the me

Page 8 - Front Panel Controls

Figure 4. Create Method Flow ChartCONSTANT VCONSTANT mACONSTANT WCREATE >>EDIT >>RUN >>VIEW >>STEP 1TIME >>V-HOUR >

Page 9 - 3.0 MANUAL MODE OPERATION

4.2 EDIT AND RUN A METHODThe Edit selection of the Program mode allows you to change an existing method.Table 5.Procedure for Editing and Running a M

Page 10 - Manual Mode Operation

Table 5. (continued)Procedure for Editing and Running a MethodStep Procedure Description17POWER PACProgram Mode Operation7. Enter the method number

Page 11

4.3 VIEW A METHODThis selection allows you to quickly view the contents of a stored method.Table 6.Procedure for Viewing a MethodStep Procedure Descr

Page 12

1POWER PACTable of ContentsTABLE OF CONTENTSSafety ...

Page 13 - 4.0 PROGRAM MODE OPERATION

4.4 RUN A METHODThis procedure allows you to quickly select and run a stored method.Table 7.Procedure for Running a Stored MethodStep Procedure Descr

Page 14 - Table 4

During operation of the power supply, the LCD display shows the operating parameter values, as shown inFigure 5. Legend1. Status of the run.2. Elapse

Page 15 - Table 4. (continued)

After the programmed time or volt-hours, the power supply automatically continues with the next step or ifthere is none, it stops. When the method st

Page 16

5.0 TEMPERATURE MODE OPERATION (POWERPAC 3000 ONLY)Temperature mode allows you to operate an electrophoresis apparatus at a constant temperature. Co

Page 17 - Table 5

Table 8. (continued)Temperature Mode OperationStep Procedure Description23POWER PACTemperature Mode Operation4. Attach the temperatureprobe to the

Page 18 - Table 5. (continued)

Table 8. (continued)Temperature Mode OperationStep Procedure Description24POWER PACTemperature Mode Operation7. Enter the desired tempera-ture in d

Page 19 - Table 6

Table 8. (continued)Temperature Mode OperationStep Procedure DescriptionTable 9.Examples of Power RequirementsThe following table shows approximate po

Page 20 - Table 7

Figure 7. Temperature Mode Flow Chart26POWER PACTemperature Mode OperationMANUAL >>PROGRAM >>TEMPERATURE >>ENTER TEMPERATUREIN D

Page 21 - POWER PAC

6.0 MAINTENANCE AND TROUBLESHOOTING6.1 MAINTENANCEPowerPac power supplies require very little maintenance to assure reliable operation. During norm

Page 22

ErrorMessage SolutionNO LOAD DETECTED The resistance to the load is too high. (It should not be greater thanSYSTEM WAS SHUT DOWN 6 mega-ohms.) CORRE

Page 23 - Temperature Mode Operation

SAFETYCaution/WarningPowerPac power supplies use high output voltages that are electrically isolated fromearth ground to minimize the risk of electric

Page 24 - Table 8. (continued)

ErrorMessage SolutionPowerPac 1000 only:OPERATING OVER 1000 V, or The voltage, current, or power output has exceeded the powerOPERATING OVER 500 mA, o

Page 25

APPENDIX A. SPECIFICATIONSNote: All specifications subject to change without notice. Input Rating:100/120 V model: 90 - 132 VAC, 47 Hz - 63 Hz220/2

Page 26 - Step Procedure Description

Readout Stability: PowerPac 1000 PowerPac 3000Volts: ±1% at 1000 V full scale ±1% at 3000 V full scaleCurrent: ±1% at 500 mA full scale ±1% at 400 mA

Page 27

Operating ConditionsTemp.: 0 - 40°CHumidity: 0 - 95% relative humidity, non-condensingDimensions: 29 (L) x 28 (W) x 11 (H) cm; unit is stackableWeight

Page 28

APPENDIX B. WARRANTY AND ORDERING INFORMATIONThe PowerPac power supply is warranted for 1 year against defects in materials and workmanship. If anyd

Page 29

WARRANTY INFORMATIONModel:Serial Number:Date of Delivery:Warranty Period:ORDERING INFORMATIONCatalogNumber Product DescriptionPowerPac 3000165-5056 Po

Page 30

Life ScienceGroupWeb site www.bio-rad.com Bio-Rad Laboratories Main Office 2000 Alfred Nobel Drive, Hercules, CA 94547, Ph. (510) 741-1000, Fx. (510)

Page 31 - APPENDIX A. SPECIFICATIONS

36POWER PACTable of Contents

Page 32

ImportantThis instrument is intended for laboratory use only.This product conforms to the class A standards for Electromagnetic Emissions, intended fo

Page 33

1.0 INTRODUCTION1.1 OVERVIEWPowerPac power supplies provide constant voltage, power, and current for electrophoresis applications.The PowerPac 3000

Page 34

PowerPac power supplies operate at the value specified by the constant parameter. However, to preventdamage to your electrophoresis cell, PowerPacs p

Page 35

2.0 CONTROL FEATURES2.1 FRONT PANEL CONTROLSTable 1.Front Panel ControlsKey DescriptionStart key: Starts a run. Stop key: Stops the run which is

Page 36 - 4006038 Rev B

Table 1. (continued)Front Panel ControlsKey DescriptionSoft keys: Allow you to select that parameter or execute that command on thegraphic display w

Page 37 - Table of Contents

3.0 MANUAL MODE OPERATIONPowerPac power supplies may be operated automatically using pre-defined methods, or may be run manu-ally at a specified volt

Comments to this Manuals

No comments